| Power | 7.5 KW |
| Horsepower | 10 HP |
| Speed | 960 rpm |
| Voltage | 415 V |
| Mounting Type | Foot cum Flange |
Minimum order quantity: 01 Piece
bharat bijli 7.5 kw 960 rpm 100% ORGINAL product
Output (kW)/Poles : / 6P Frame Size : Voltage (V) : +/- 10% Area Classification : Frequency (Hz) : +/- 5% Type of Ex Protection : Duty : Gas group / Temp. Class : / Altitude (m) : Approving Authority : Amb Temp/ Temp Rise : / Enclosure / Cooling Type : / Insulation Class : Location-Indoor/Outdoor : Temp. Rise Class on DOL : Mounting : Rated Current (Amps) : Degree of protection : Rated Speed (RPM) : T Box Position from DE : Rated Torque (kgm) : Type of coupling : Service Factor (SF) : Type of Bearing (DE/NDE) : / SF Current (Amps) : DE / NDE Bearing : / Efficiency & Power factor : Lubrication : % Full Load % Efficiency Power Factor Connection / No. of terminals : / 6 100% IE2 Cable Size : Sqmm 75% Main T.Box ET Size : 50% Weight in kg (Approx) : Locked Rotor Current (% Full Load) : Direction of rotation : Locked Rotor Torque (% Full Load) : Paint Type : Breakdown Torque (% Full Load) : Paint Shade : L.R. Withstand Time Hot/Cold (sec) : 15 / 30 Noise level (dBA) : Application : Vibration level (mm/sec) : Type of Load Torque : Brake Type : Method of starting : Braking Torque (kgm) : Speed Variation on VFD : Brake release time (ms) : Rotor GD2 (kgm2 ) : Brake application time (ms) : Load RPM : Accessories : Load GD2 (kgm2 ) : Starting time (sec) : 1.3 0.4 No. of consecutive starts : 2 3 Additional data 1 : Additional data 2 : Applicable Standards : IS/IEC60034-1, IS12615, IS1231, IS2223, IS12065, IS12075 Remarks : Notes 1) All performance values are subject to IS/IEC 60034-1 tolerances, unless otherwise specified. 2) Performance values are at rated voltage and rated frequency condition and for DOL starting condition. 3) Motor GD2 = Load GD2 assumed wherever not mentioned. 4) Where starting time is more than 10 seconds, provision of heavy duty relays is mandatory. Notes for VFD Motors 3) Switching frequency should not exceed 5.0 kHz 4) For constant torque application, voltage boost is necessary for frequencies <= 17Hz 5) Temperature rise of motor by resistance measurement with VFD supply will be limited to class F limit. 5.500K6P2HLAXXAAX / 2H13M6TACTSSX 85.0 Delta 6208 2Z 6208 2Z Lithium Soap Base Grease 86.0 2 x 3C x 6 86.0 2 x 1 inch BSC 80 132M Safe Area N.A. N.A. Indoor TEFC IC411 Line Operated IE2 Efficiency Motor DATA SHEET 3 Phase Squirrel Cage Induction Motor - - - Nos - - - 1) Motors suitable to run on VFD supply are designed with an insulation system suitable for withstanding voltage of 1.56 kV (peak phase to phase) and rise time > = 0.1 micro sec. 0 MCG MCG 29-04-2023 Rev No. Checked By Date Prepared By 2) The customer / his system integrator have to ensure that the voltage at motor terminals shall not exceed above limit by properly selecting cable length and using suitable filters / choke. 5.5 N.A. N.A. N.A. F 11.6 960 5.58 0.60 0.71 0.77 S1 (Continuous)